Coolblock Archemedes:
Immersion Cooling Made Practical

Archemedes

Ideal for companies or organizations with big data center infrastructure, that want to operate more efficiently and lower their carbon footprint.

The benefits of Archemedes

Achieve PUE < 1,03

Achieve PUE < 1,03

PUE is the ultimate metric highlighting the efficiency of a data center. Air-Cooling DC hit its best rating PUE around 1.5-1.7. COOLBLOCK can achieve at least 60% more efficiency with PUE<1.03

Reduce your CAPEX & OPEX

Reduce your CAPEX & OPEX

COOLBLOCK powered Data Centers need leaner infrastructure to support the desired workload. Eliminate need for cold/hot isles, air moving components etc. OPEX costs drop significantly also, less power consumed on cooling, less and simpler maintenance procedures.

Unparalleled density

Unparalleled density

Choose the solution that fits your needs with up to 50 kW per standalone system (ARCHEMEDES). The Liquid Coolant allows you to handle heavy loads without harming your IT equipment, increasing the computational density and operational stability.

Modularity - Scalable anytime

Modularity - Scalable anytime

Start from one COOLBLOCK ARCHEMEDES and add more - anytime, anywhere. COOLBLOCK’s solutions are autonomous and installable in any possible location without disturbing already existing equipment. You can run your Data Center as is, and replace step by step your air-cooling systems with energy efficient and cost saving solutions from COOLBLOCK.

Increase HW Lifetime +30%

Increase HW Lifetime +30%

With COOLBLOCK’s Liquid Coolant and edge cooling technology, your IT equipment is protected not only from Oxidization and dust particles but also from heat shocks due to the uniformity of controlled heat dissipation. HW operates under stable and safe conditions that adjust automatically to the heat load.

-60% IT Failure

-60% IT Failure

COOLBLOCK’s Liquid Coolant eliminates the root cause of most electronic component failures - Oxidization and Heat Shocks. Air-Cooling Systems expose HW to Oxygen and Dust, leading to early failure, while the random currents of air cool the HW indifferent percentages. The Liquid Coolant provides a homogenous heat dissipation, while it keeps HW safe from Oxygen.

Autonomous Installation Anywhere

Autonomous Installation Anywhere

Save up to 60% from Construction Costs. No need for soundproof rooms or secluded buildings - COOLBLOCK’s solutions can bein stalled anywhere without any special installations.  Be it an office, on a rooftop, inside an existing Data Center.

- 95% Cooling Costs

-95% Cooling Costs

With COOLBLOCK’s deployment of the latest single phase liquid cooling technology and the incomparable efficiency of our systems, energy losses are minimized and costs can drop up to 95%. Lower Electricity bills up to -60%.

Zero waste of water

Zero waste of water

Water is an essential resource for any datacenter operations as important as electricity. COOLBLOCK’s system guarantees zero water consumption thanks to the closed loop of the secondary cooling system, that also guarantees no corrosion and avoids any water evaporation.

Zero Noise

Zero Noise

By disposing the air fans, the noise levels drop to zero. With COOLBLOCK single phase liquid immersion cooling, you can have your Data Center in your own office and work undisturbed, having direct monitoring. Separate rooms or building for storing your IT equipment becomes unnecessary, working environment becomes friendlier and facility costs drop significantly.

Archemedes

Archemedes U20
20 units
Archemedes U44
44 units
COOLBLOCK | PRODUCT ARCHEMEDES  U20-U44
COOLBLOCK | PRODUCT ARCHEMEDES

Archemedes

TECHNICAL SPECS

Heat dissipation capacity (kW)
50 to 100 kW
Double tank IT gear capacity (U)
20 U to 44 U
Maximum power consumption (W)
750 W to 1500 W
Built-in redundancy
2N Pump
Power supply
(CE) 3 Phase + N / 380-400 V 50 Hz (UL) 3 Phase
208 V 60 Hz
Monitoring and Control
Temperature and flow for both Liquid and water
(input - output)
Water supply inlet temperature
Recommended ≤ 32 ºC
89.6 ºF
Environmental conditions
Indoors -20°C to 55°C non-condensing
Water flow rate
Technical 1 - 8  m3/s
Water input (depends on IT)
Typical  40 - 50 °C
Communications
Remote control with Ethernet port Multiple options for integrated pass-through patch panel and cable management
Dimensions
135 (L) x 85 (W) x 122 (H) cm
54.2 (L) x 33.5 (W) x 48 (H) in
COOLBLOCK | PRODUCT ARCHEMEDES  DIMENSIONSCOOLBLOCK | PRODUCT ARCHEMEDES  DIMENSIONSCOOLBLOCK | PRODUCT ARCHEMEDES  DIMENSIONS

Archemedes

Compact Design

Archemedes

Accessible
Control Panel

Archemedes

Compact Design

Archemedes

All-in-one
Cable Outlet

Archemedes

Custom made
frames

Archemedes

Simple Control

Archemedes

Transparent Lid
for Visibility 